TM 5-6115-596-14
Table 5-5.
Component
Circuit
(OHMS)
PS-18 and 19 to
Over 500
case
PS-16 to case
Infinite
PS-12 to case
2
PS-11 to case
100 to 150
Voltage regulator assembly
CR-2 to CR-18
Less than 1
(Generator set, serial num-
bers 923-001 thru 923-553)
CR-18 to case
45 to 50
I
I
CR-18 to CR-5
10 to 15
5-30 .
Inspection and Repair.
(Serial numbers 923-001 thru 923-553
Only) .
a.
Inspection.
(1) Inspect voltage regulator assembly for electrical continu-
ity as described in electrical troubleshooting (para. 4-9) .
Replace
regulator assembly if defective.
(2) Check external connectors for evidence of damage to
threads, pins, and sockets.
Replace connectors if damaged.
(3) Inspect cover, case, and base plate for deep dents and
distortion of surfaces.
Replace components that show either of
these defects.
(4) Check relay assembly, voltage regulator assembly, and
Replace
cable assemblies for burned, worn or frayed insulation.
components that show any one of these defects.
screws and threaded parts for crossed, worn, or
(5) Inspect
Rep1ace parts if damage is beyond repair.
damaged threads.
Repair of the generator components consists of re-
b.
Repair.
placing parts that do not pass visual inspection and have not retained
Change 2
5-49