TM 5-6115-596-14
.
If replacement regulator (generator sets, serial numbers 923-
001 thru 923-553) is to be installed, remove four brackets (7) from
defective regulator.
f.1.
If replacement regulator (generator sets, serial numbers
929-001 thru 929-290) is to be installed, remove two brackets (7)
from defective regulator.
5-29.
(Serial numbers 923-001 thru 923-553 only).
Disassembly.
a.
Remove wire seal (2), six screws (3), and lockwashers (4),
and remove regulator cover (1) and gasket (5) from case (13).
Discard wire seal and gasket.
b.
Remove two nuts (8), lockwashers (9), and flat washers (10),
and disconnect two bus bars (11) from relay assembly (6).
Remove screw (27), lockwasher (28), and flat washers (29),
c.
and disconnect clamp (30) and cable assemblies (16) from relay
assembly (6) and voltage regulator assembly (22).
d.
Remove wire seal (20), six screws (19), and lockwashers (18),
and remove base plate (21) with relay assembly (6), voltage regu-
Discard wire
lator assembly (22), and gasket (25) from case (13).
seal and gasket.
e.
Remove four screws (12) and remove two bus bars (11) from
inside of case.
f.
Remove eight screws (17) and remove two cable assemblies (16)
Discard gaskets.
and gaskets (26) from case.
Remove six screws (7) and remove relay assembly from base
g.
plate (21).
h.
Remove bolt (24) and washer (23) and remove voltage regulator
assembly from base plate.
Change 2
5-45