TM 5-6115-275-14
NAVFAC P-8-615-14
TO 35C2-3-452-1
Figure 4-80. Air baffles, removal and installation (Model MEP-018A).
b.
Cleaning, Inspection and Repair.
WARNING
Clean all parts in a well-ventilated
area. Avoid inhalation of solvent
fumes and prolonged exposure of
skin to cleaning solvent. Wash
exposed
skin
thoroughly.
Dry
cleaning solvent (Fed. Spec. P-D-680
and P-S-661) used to clean parts is
potentially dangerous to personnel
and property. Do not use near open
flame or excessive heat. Flash point
of solvent is 100°F (38°C).
(1)
Clean baffles with cleaning solvent,
Fed. Spec. P-D-680 or P-S-66 1, and dry thoroughly.
(2)
Inspect for cracks, breaks or other
damage. Replace a defective baffle.
c.
Installation.
(1)
Install the air baffles as shown by
figure 4-80.
(2)
Install the control cabinet (fig. 4-79).
(3)
Install the battery (fig. 4-78).
4-56.
Toolbox,
Toolbox
Bracket,
Lifting
Eye,
Bracket, Guard Frame, and Vibration Mounts
(Model MEP-023A)
a.
Removal. Refer to figure 4-81 and remove
toolbox, brackets, mounts, and rail guard.
Change 8 4-91