TM 5-6115-275-14NAVFAC P-8-615-14TO 35C2-3-452-1Figure 4-80. Air baffles, removal and installation (Model MEP-018A).b.Cleaning, Inspection and Repair.WARNINGClean all parts in a well-ventilatedarea. Avoid inhalation of solventfumes and prolonged exposure ofskin to cleaning solvent. Washexposed skin thoroughly. Drycleaning solvent (Fed. Spec. P-D-680and P-S-661) used to clean parts ispotentially dangerous to personneland property. Do not use near openflame or excessive heat. Flash pointof solvent is 100°F (38°C).(1)Clean baffles with cleaning solvent,Fed. Spec. P-D-680 or P-S-66 1, and dry thoroughly.(2)Inspect for cracks, breaks or otherdamage. Replace a defective baffle.c.Installation.(1)Install the air baffles as shown byfigure 4-80.(2)Install the control cabinet (fig. 4-79).(3)Install the battery (fig. 4-78).4-56.Toolbox, Toolbox Bracket, Lifting Eye,Bracket, Guard Frame, and Vibration Mounts(Model MEP-023A)a.Removal.Refer to figure 4-81 and removetoolbox, brackets, mounts, and rail guard.Change 8 4-91