TM 5-6115-596-14
4-36.
a.
Removal.
(1) Make certain all power is turned OFF.
NOTE
When removing wiring harness, it may
be necessary to remove tie-straps.
Make certain straps are replaced when
wiring harness is installed.
(2) Disconnect regulator battery connector (12) at generator
regulator (13).
(3) Disconnect relay-to-regulator battery connector lead (5) at
(4) Remove 8 screws (14), nuts (15), and 16 washers (16), and
remove 2 power receptacles (1) from control panel (3) and outer
frame (10).
(5) Remove nut (8) and three washers (9) and disconnect two
circuit 50 leads (11) and ground lead (7) at starter-generator (6).
(6) Disconnect leads (17) at engine start switch (2).
(7) (For generator sets serial numbers 923-001 thru 923-553).
Disconnect circuit 950.lead (21) and circuit 950A lead (4) at
rheostat connectors (20).
(8) Remove wiring harness (18) from generator set.