TM 5-6115-596-14
Inspect wires, terminals, connectors,
Inspection and Repair.
b.
and receptacles for cracks, breaks, burned areas, and worn or damaged
insulation.
If wires, terminals, connectors, or receptacles show any
one of these defects, repair wiring harness as described in paragraph
4-32.
Installation.
c.
(1) Position wiring harness (18) to generator set, and connect
relay-to-regulator battery connector lead (5) to relay (19).
(2) Connect leads (17) to engine start switch (2).
(3) Install 2 power receptacles (1) to control panel (3) and
outer frame (10) with 16 washers (16), 8 screws (14) and nuts (15).
(4) Connect regulator battery connector (12) to generator
regulator (13).
(5) Connect two circuit 50 leads (11) and ground lead (7) to
starter-generator (6), and install three washers (9) and nut (8).
I
(For generator sets serial numbers 923-001 thru 923-553).
(6)
Connect circuit 950 lead (21) and circuit 950A lead (4) tO rheostat
connectors (20) .
Change 2
4-42