TM 5-6115-596-14
Remove two screws (11), and remove capacitor (3) from filter
f.
housing.
Remove two screws (11), and remove capacitor (31) from filter
g.
housing.
Remove screw (33), two nuts (4), and three washers (5), and
h.
remove ground strap (32) from filter housing.
i.
Loosen screw on brush covers band (15), and remove band from
generator housing.
Remove lockwire (24) between each two screws, 12 screws (23),
j.
and washers (22), and remove fan cover (25) from generator housing.
Discard lockwire.
k.
Remove fan outer nut (47) and fan inner nut (46), and remove
fan washer (45) and fan (21) from armature (28).
Remove lockwire, (20) between each two screws and six screws
l.
(19), and remove brush support retainer (44) from bearing and brush
support (18).
Discard lockwire.
Remove six screws (16), and disconnect six brush assemblies
m.
n.
Remove armature (28) with bearing and brush support (18) from
generator housing (14).
o.
Remove six brush assemblies from support.
Remove key (48) from shaft of armature, and remove support
P.
baffle (27) from armature.
Press on outside race of commutator-end ball bearing (26), and
q.
separate bearing from support.
NOTE
Do not follow r below unless inspec-
tion indicates otherwise.
5-26