TM5-6115-696-14
Check starter-generator as described
Inspection and Repair.
b.
Replace generator if
defective.
c.
Installation.
(1) Position generator to inner frame (9), and loosely install
four washers (7) and two screws (8).
(2) Loosely install two washers (1) and screw (17) securing
drive belt brace (16) to generator.
(4) Connect two circuit 50 leads (11) and ground lead (4) to
generator, and install three washers (12) and nut (10).
(5) Connect circuit 478 lead (3), circuit 2 lead (2), and
circuit 1 lead (13) to generator, and install three washers (15) and
nuts (14).
NOTE
Record on DA Form 2408-3 (Equip-
ment Maintenance Record) if re-
placement generator-starter has
been installed.
5-19.
Removal and Installation of Starter-Generator Belt Drive
Sheave and Bushing (fig. 5-6).
a.
Removal.
(1) Remove two setscrews retaining bushing and sheave to drive
shaft of generator.
(2) Using one setscrew as jack screw in threaded puller hole,
tighten and push sheave from bushing.
(3) Remove jack screw, sheave, bushing, and key from drive
shaft of generator.
5-21