TM 5-6115-596-14
(3) Inspect rheostat for any external damage that would cause
Replace rheostat that shows damage.
it not to function properly.
c.
Engine Start Switch.
(1) Inspect switch for electrical continuity as described in
Replace switch if defective.
(2) Inspect switch for any external damage that would cause it
Replace switch that shows damage.
not to function properly.
4-30.
a.
Position engine start switch (15) to control panel (8) and
secure with hex nut (1).
b.
For generator sets with serial numbers 923-001 thru 923-553,
position voltage control rheostat (10) and two spacers (9) to panel
and secure with two flat washers (7), lockwashers (6), and
screws (5).
1 - Relay-to-regulator battery
12 - Regulator ground lead nut
connector lead
13 - Regulator ground lead
2 - Relay and housing assembly
washer
3 - Regulator ground lead screw
14 - Relay-to-start switch lead
4 - Power receptacle
15 - Power receptacle screw
5 - Control panel
16 - Power receptacle nut
6 - Engine start switch
17 - Power receptacle washer
7 - Rheostat connector
18 - Engine start switch lead
8 - Circuit 950 lead
19 - Relay-to-regulator
9 - Control panel screw
lead
10 - Control panel washer
20 - Circuit 950A lead
11 - Outer frame
21 - Regulator ground lead
Change 2
4-30