TM 5-6115-596-14
Control Panel Repair.
4-24.
General .
4-25.
Scope.
This section contains instructions for removal, dis-
a.
assembly, inspection and repair, assembly, and installation of the
control panel.
The control panel assembly is an open-type
Description.
b.
panel which mounts the voltage control rheostat (generator sets,
serial numbers 923-001 thru 923-553), engine start switch, and
relay and housing assembly.
4-26.
NOTE
It is not necessary to remove the
control panel to remove any one of
Refer to paragraphs
the controls.
4-27 for removal of control parts.
a.
Disconnect relay-to-start lead (14) and relay-to-regulator
battery connector lead at relay (2).
b.
Remove four screws (15), nuts (16), and eight washers (17),
and remove power receptacle (4) from control panel (5).
c.
For generator sets with serial numbers 923-001 thru 923-553
disconnect circuit 950 lead (8) and circuit 950A lead (20) at
rheostat connectors (7).
d.
Disconnect leads (18) at engine start switch (6).
Remove screw (3), nut (12), and two washers (13), and
e.
disconnect regulator ground lead (21) at relay.
f.
Disconnect relay-to-regulator generator connector lead (19)
at relay.
Change 2
4-28