TS 022262
TS 022263
TM 5-6115-329-14
TO 35C2-3-440-1
Figure 4-16. Measuring DC voltage.
(c) Read the Meter. (The example (fig.4-
17) show how to read all three multimeters). If the
needle tries to move off scale to the left, reverse the
probes on the circuit.
1. Simpson 160. Read the DC volts
scale for the range the selector switch is set at.
Switch Setting
Scale
V/DC 50
0-50
V/DC 10
0-10
V/DC 2.5
0-25 (and divide by 10)
Thus, the meter (fig. 4-17, sheet 1 of 3) is showing
the following readings:
Figure 4-17. Reading DC voltage (sheet 1 of 3).
4-24