TM 5-6115-596-14
f.
Install six brush assemblies (17) in support.
Install armature with support in generator housing (14).
g,
Connect brush assemblies to generator brush terminals (37)
h.
with six screws (16).
i.
Position brush support retainer (44) to support on armature
and secure with six screws (19) and new lockwire (20) between each
two screws.
Position fan (21) and fan washer (45) to support and secure
j.
to shaft or armature with fan inner nut (46) and fan outer nut (47)
Position fan cover (25) to generator housing and secure with
k.
12 washers (22), screws (23), and new lockwire (24) between each two
screws.
1.
Install brush cover band (15) on generator housing.
Position ground strap (32) to inside of radio-noise suppres-
m.
sion filter housing (13) and secure with screw (33), three washers
(5), and two nuts (4).
n.
Position one-pole capacitor (31) to filter housing and secure
with two screws (11).
o.
Position two-pole capacitor (3) to filter housing and secure
with two screws (11).
Position filter housing to generator housing and secure with
p.
four washers (12) and screws (10).
Connect ground strap (32) and one-pole capacitor (31) to
q.
generator terminals (34) with two screws (6), washers (29), and nuts
(30).
r.
Connect circuit A lead (35) and circuit D lead (36) to two-
pole capacitor (3) with two washers (2) and nuts (l).
s.
Secure filter housing cover (7) to housing (13) with eight
washers (8) and screws (9).
5-38