TM 5-6115-434-12
System no. 2 (upper), for recharge only...............................180 cc (approx)
Refrigeration compressors: (2 used)
Manufacturer .......................................................................AiResearch Manufacturing Company of Los Angeles
Part number ........................................................................572030-1-2
Type ....................................................................................Two stage centrifugal
Rpm ....................................................................................23,300
Duty cycle ...........................................................................Continuous
Volts ....................................................................................120/208
Frequency ...........................................................................400 Hz
Phase ..................................................................................3
Amps...................................................................................60
Refrigerant receivers: (2 used)
Manufacturer .......................................................................AiResearch Manufacturing Company of Los Angeles
Part .....................................................................................184270-1-1
Refrigerant condensers: (2 used)
Manufacturer .......................................................................AiResearch Manufacturing Company of Los Angeles
Part number ........................................................................184260-11
Type ....................................................................................Aluminum plate fin
Refrigerant evaporators: (2 used)
Manufacturer .......................................................................AiResearch Manufacturing Company of Los Angeles
Part number ........................................................................184250-1-1
Type ....................................................................................Aluminum plate fin
Condenser cooling fan: (4 used)
Manufacturer .......................................................................AiResearch Manufacturing Company of Los Angeles
Part number ........................................................................605890-3-1
Type ....................................................................................Single stage, axial flow
Rating..................................................................................5500 cfm at 2.15 in. of H2O static pressure
Rpm ....................................................................................3800
Volts ....................................................................................120/208
Frequency ............................................................................400 Hz
Phase ..................................................................................3
Amps...................................................................................15
Recirculating fan: (4 used)
Manufacturer .......................................................................AiResearch Manufacturing Company of Los Angeles
Part number ........................................................................605370-1-2
Type ....................................................................................Single stage, axial flow
Rating..................................................................................1620 cfm at 3.45 in. of H2O static pressure
Rpm ....................................................................................5700
Volts ....................................................................................120/208
Frequency ...........................................................................400 Hz
Phase ..................................................................................3
Amps..................................................................................._6.0
(7)
Water system.
Hot water pressure at outlet connection....................................10 psig
Hot war, flow (with no cold water flowing) .................................6 gpm
Cold water pressure at outlet connection ..................................10 psig
Cold water flow (with no hot water flowing) ...............................9 gpm
Heat exchanger heating capacity .............................................60,000 btu/hr at sea level and ambient temperature -650F (-54
C)
Hot water storage tank capacity................................................15 gal (approx)
Hot water temperature at outlet connection ..............................1400 to 1600F (600 to720C)
Temperature--pressure relief valve setting ...............................2000F (930C), 75 psig
High pressure relief valve setting .............................................100 psig
Surge tank pressure switch actuation .......................................40 to 45 psig
(8)
Compressed air system.
Normal external discharge pressure .........................................55 to 110 in. Hg A
Pressure through inflation ejector .............................................1.5 psig (min)
Flow through inflation ejector ...................................................200 scfm (min)
(9)
Vacuum system.
Vacuum source ........................................................................Compressed air through eductor
Suction by eductor ...................................................................10 scfm at 18 to 20 in. Hg A
(10)
Engine fuel and bleed-air control systems schematic. Refer to figure 1-4.
(11)
Engine electrical system schematic. Refer to figure 1-5.
(12)
Engine lubrication system schematic. Refer to figure 1-6.
(13)
Power unit electrical system schematic. Refer to figure 1-8.
(14)
Cooled air system schematic. Refer to figure 1-10.
(15)
Heated air system schematic. Refer to figure 1-11.
(16)
Water system schematic. Refer to figure 1-13.
(17)
Instrument panel practical wiring diagram. Refer to figure 1-17.
1-32