Figure 5-8. Removal of starter fan housing.
Figure 5-10. Generator removal.

Generator Set, Gas Engine: 0.125 Kw, Ac, 115 V, Single Phase, 400 Cycle; Special Purpose; Portable; W/Carrying Case Page Navigation
  31    32    33    34    35  36  37    38    39    40    41  
img
. . .
TM 5-6115-405-15
Figure 5-9. Using rotor locking tool to hold shaft.
(7) Hold generator rotor to keep the shaft
b. Installation (fig. 5-10).
from turning, and install and tighten
(1) Insert stator leads through grommets in
socket head screw, lockwasher, and flat
stator mounting plate and drivecase.
washer.
(2) Check that needle bearing and generator
stator are installed, and secure stator
Caution
mounting plate to drivecase with left-hand
Do not use rotor locking tool to
side screws only.
tighten screw.
(3) Secure stator leads under cable clamp on
drivecase and connect leads to output
5-13. Ignition Ports
connector.
a. Removal.
(4) Secure output connector to junction box.
(1) Remove starter fan housing as described
(5) Position junction box over stator mounting
in paragraph 5-11.
plate and secure two remaining screws.
(2) Remove air screen by taking off two self-
(6) Aline keyway in generator rotor with
locking nuts.
keyway in shaft and mount generator rotor
(3) Connect the fabricated rotor locking tool
in position. Insert key in keyway.
to the magneto rotor in the manner shown
in figure 5-11.