TM 5-6115-405-15
CHAPTER 4
DIRECT AND GENERAL SUPPORT AND DEPOT
MAINTENANCE INSTRUCTIONS
Section I. GENERAL
4-2. Record and Report Forms
4-1. Scope
For record and report forms applicable to direct and
These instructions are published for the use of direct
general support and depot maintenance, refer to TM 38-
and general support and depot maintenance personnel
750.
maintaining the Homelite Model XLA115/1/400-1P
generator set.
They provide information on the
Note.
maintenance of the equipment, which is beyond the
Applicable
forms,
excluding
scope of tools, equipment, personnel, or supplies
Standard Form 46 (United States
normally available to using organizations.
Government
Motor
Vehicle
Operator's identification card) which
is carried by the operator, shall be
kept in the publications case
mounted in the carrying case cover.
Section II. DESCRIPTION AND TABULATED DATA
Wire size ..................................No 21 AWG
4-3. Description
Type of wire ..........................Heavy Formvar or equal
Insulating materials ...............Shell epoxy 828 or equal
For a complete description of the generator set see
Lead wire length ....................8 in.
End treatment .......................Solder-dip
4-4. Tabulated Data
Spark plug ................................250-330 in. lb
a. General.
This paragraph contains all the
Connecting rod cap ................... 55-60 in. lb
overhaul data pertinent to direct and general support
screws.
Magneto rotor nut .....................150-200 in. lb
practical wiring diagram of the generator set.
No. 4 spinlock screws ..............5 in lb min
b. Generator classification and rating
No. 6 spinlock screws ..............20 in. lb min
No. 8 spinlock screws ..............36 in. lb min
Type..........................................Permanent magnet
No 10 spinlock screws ..............50 in. lb min
Rating ....................................... 125 watts
No. 12 spinlock screws ............80 in. lb min
Output voltage .......................... 115 volts ac
1/4 in. spinlock screws .............120 in. lb min
Phase........................................ Single
No. 4-40 ordinary
4 3/4 in. lb min
Power factor .............................1.0
screws.
Frequency ................................400 cps
No 6-32 ordinary
8 3/4 in. lb min
Cooling ....................................Air
screws.
c. Generator stator -repair standards.
No. 8-32 ordinary
18 in. lb min
Number of poles .......................12
screws
Number of coils ........................45
No 8-36 ordinary
20 in. lb min
Turns per coil ...........................7
screws.
No. 10-24 ordinary
23 in. lb min
screws.
4-1