• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Operation in Extreme Heat
Daily Preventive Maintenance Services

Generator Set, Gas Engine: 0.125 Kw, Ac, 115 V, Single Phase, 400 Cycle; Special Purpose; Portable; W/Carrying Case Page Navigation
  9    10    11    12    13  14  15    16    17    18    19  
img
. . . . . .
TM 5-6115-405-15
CHAPTER 3
OPERATOR AND ORGANIZATIONAL MAINTENANCE
INSTRUCTIONS
Section I. SPECIAL TOOLS AND EQUIPMENT
clean out clogged perforations of the muffler as
3-1. Special Tools and Equipment
described in paragraph 3-8 and as shown in figure 3-4.
The only special tool required by operator or
3-2. Basic Issue Tools and Equipment
organizational maintenance personnel for maintenance
of the generator set is a muffler cleaning tool, which can
be fabricated as shown in figure 3-1 The tool is used to
Repair parts issued with the generator set are listed
in the basic issue items list, appendix B of this manual.
Figure 3-1. Fabrication of muffler cleaning tool
Section II. PREVENTIVE MAINTENANCE SERVICES
corrected before they result in serious damage or
3-3. General
failure.
The  necessary  preventive  maintenance
services to be performed are listed and described in
To insure that the generator set is ready for
paragraphs 3-4 and 3-5.  Item numbers indicate the
operation  at  all  times,  it  must  be  inspected
sequence of minimum inspection requirements. Defects
systematically so that defects may be discovered and
3-1