• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Daily Preventive Maintenance Services
Section III. OPERATOR'S MAINTENANCE

Generator Set, Gas Engine: 0.125 Kw, Ac, 115 V, Single Phase, 400 Cycle; Special Purpose; Portable; W/Carrying Case Page Navigation
  11    12    13    14    15  16  17    18    19    20    21  
img
. . . . . . . . . . .
TM 5-6115-405-15
ITEM
PAR REF
1
AIR CLEANER ELEMENT. SERVICE AIR CLEANER ELEMENT.
3-7
1
AIR CLEANER ELEMENT. REPLACE AIR CLEANER ELEMENT. (100 HOURS)
3-7
2
SPARK PLUG. CLEAN AND REGAP. (30 HOURS)
3-11
2
SPARK PLUG. REPLACE. (50 HOURS)
3-11
3
CYLINDER FINS. CLEAN CYLINDER FINS. (WEEKLY)
3-9
4
CYLINDER EXHAUST PORT. CLEAN CYLINDER EXHAUST PORT. (T0 HOURS)
3-9
5
EXHAUST MANIFOLD. CLEAN EXHAUST MANIFOLD. (50 HOURS)
3-9
6
MUFFLER. CLEAN MUFFLER. (50 HOURS)
3-8
7
GOVERNOR. CHECK GOVERNOR AND ADJUST SPEED. (50 HOURS)
3-12
8
FUEL LINES. INSPECT LINES FOR DAMAGE. REPLACE IF DAMAGED.
3-10
9
FUEL TANK. ADD FUEL AS REQUIRED.
2-5c
Figure 3-2. Daily preventive maintenance series.
3-3