TM 5-6115-332-14
P-8-614-14
TO 35C2-3-424-1
Table 4-3. Organizational Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8. GENERATOR OVERHEATS
Check the engine shrouds and cooling fins by observation.
See if there is a blockage or obstruction.
If air passages are obstructed, clean them.
9. GENERATOR SET NOISY
Check the mounts by moving slightly.
If mounts are loose or cracked, refer to paragraph 4-44 for removal and installation
instructions.
10. PANEL LIGHTS FAIL TO OPERATE
Step 1.
Check for loose connections. Inspect for worn or broken wiring.
Refer to paragraph 4-39 for repair instructions.
Step 2.
Check for a broken or cracked panel light switch. Check for worn or broken wiring.
Refer to paragraph 4-31 for removal and installation instructions.
11. TIME TOTALIZING METER FAILS TO OPERATE OR IS INACCURATE
Step 1.
Check for loose connections and broken or worn wiring.
Refer to paragraph 4-39 for repair instructions.
Step 2.
Check for a broken or cracked time toalizing meter.
Check for loose or broken wiring.
Refer to paragraph 4-25 for removal and installation instructions.
12. BATTERY CHARGING AMMETER GIVES NO READING OR GIVES INACCURATE
READING
Step 1.
Check for loose connections at the wiring by observing or slightly moving the harness. Also
check for broken or worn wiring.
Refer to paragraph 4-39 for repair instructions.
Step 2.
Check for cracked or broken battery charging ammeter. Test ammeter leads with a multimeter,
for continuity.
Refer to paragraph 4-29 for removal and installation instructions.
13. OIL PRESSURE INDICATOR FAILS TO INDICATE OR GIVES LOW READING
Step 1.
Check for loose connections by observing visually or move harness slightly to indicate loose con-
necting points.
Check all wiring to see if it is worn or broken,
Refer to paragraph 4-39 for repair instructions.
Step 2.
Check indicator for cracked or broken glass, bent needle, or damaged wiring.
Refer to paragraph 4-26 for removal and installation instructions.
Step 3.
Check for proper operation of relay K2 and K4.
Refer to paragraph 4-42 for removal and installation instructions.
4-40
Change 7