TM 5-6115-275-14
NAVFAC P-8-615-14
TO 35C2-3-452-1
b.
Cleaning, Inspection and Repair.
WARNING
l parts in a well-ventilated area. Avoid inhalation of
solvent
fumes
and
prolonged
exposure of skin to cleaning solvent.
Wash exposed skin thoroughly. Dry
cleaning solvent (Fed. Spec. P-D-680
and P-S-661) used to clean parts is
potentially dangerous to personnel
and property. Do not use near open
flame or excessive heat. Flash point
of solvent is 100°F (38°C).
(1)
Clean metal items with cleaning
solvent, Fed, Spec, P-D-680 or P-
S-66 1, and dry thoroughly.
(2)
Inspect
for
cracks,
breaks,
damaged threads, corrosion, and
other damage.
(3)
Replace
a
defective
terminal
board.
c.
Installation. Refer to figure 4-69 and install
the remote control terminal board.
4-45.
Remote
Terminals
Drip
Cover,
Circuit
Breaker Drip Cover, And Load Terminals
Cover (Model MEP-018A)
a.
Removal. Refer to figure 4-70 and remove
covers.
b.
Cleaning, Inspection and Repair.
WARNING
l parts in a well-ventilated area. Avoid inhalation of
solvent
fumes
and
prolonged
exposure of skin to cleaning solvent.
Wash exposed skin thoroughly. Dry
cleaning solvent (Fed. spec. P-D-680
and P-S-661) used to clean parts is
potentially dangerous to personnel
and property. Do not use near pen
flame or excessive heat. Flash point
of solvent is 100°F (38°C).
(1) Clean items with cleaning solvent, Fed.
Spec. P-D-680 or P-S-66 1, and
dry thoroughly.
(2) Inspect for cracks, breaks or other
damage. Replace all defective
parts.
c.
Installation. Refer to figure 4-70 and install
items.
Figure 4-70. Remote terminals drip cover. circuit
breaker drip cover, and load terminals
cover, removal and installation (Model
MEP-018A).
Change 8 4-81