TM 5-6115-332-14
P-8-614-14
TO 35C2-3-424-1
b. Cleaning, Inspection and Repair.
Clean all parts in a well-ventilated area.
Avoid inhalation of solvent fumes and pro-
longed exposure of skin to cleaning sol-
vent. Wash exposed skin thoroughly. Dry
cleaning solvent (Fed. Spec. P-D-680, Type
II) used to clean parts is potentially
dangerous to personnel and property. Do
not use near open flame or excessive heat.
Flash point of solvent is 140 F (60° C).
(1) Clean items with cleaning solvent Fed.
Spec. P-D-680 Type II, and dry thoroughly.
(2) Inspect studs for cracks, breaks and wear.
(3) Replace a damaged stud.
c. Installation. Install ground terminal stud to
skid base using lockwasher and nut.
d. Replace lost or broken terminal clip (Retainer,
safety clip). For fabrication procedures, see paragraph
4-45A.
4-50. Toolbox
a. Removal. Refer to figure 4-31 and the following in-
structions to remove the toolbox.
(1) Remove the nuts, lockwashers, and screws
which secure the toolbox to the toolbox mounting
bracket.
(2) Remove the toolbox.
b. Cleaning, Inspection and Repair.
WARNING
Clean all parts in a well-ventilated area.
Avoid inhalation of solvent fumes and pro-
longed exposure of skin to cleaning sol-
vent. Wash exposed skin thoroughly. Dry
cleaning solvent (Fed. Spec. P-D-MO, Type
11) used to clean parts is potentially
dangerous to personnel and property. Do
not use near open flame or excessive heat.
Flash point of solvent is 140° F (60° C).
(1) Clean items with cleaning solvent Fed.
Spec. P-D-680 Type H, and dry thoroughly.
(2) Inspect the toolbox for dents, broken welds
and other damage.
(3) Weld cracks and grind the weld smooth.
(4) Straighten dents.
(5) Replace a defective toolbox.
c. Installation.
(1) Position toolbox in place on toolbox mount-
ing bracket.
(2) Secure with screws, lockwashers and nuts.
4-68
Change 6