TM
5-6115-329-25P
Code
Used on
ber in the index. The earliest figure and item
B
0.5 KW, Military Design, 400 Hertz, DOD
number is the referenced item. Items authorized
Model MEP-019A, serial number range
for use as required but not for initial stockage are
JB66-001 through JB66-4370, formerly
identified with an asterisk in the allowance
Military Model HF-0.5-MD, FSN 6115-
column.
917-7354.
0.5 KW, Military Design, 60 Hertz, DOD
C
(2) The quantitative allowances for DS/GS
Model MEP-014A, serial number range
l e v e l s of maintenance will represent initial stock-
BA68-001 through BA68-0951, formerly
a g e for a 30-day period for the number of equip-
Military Model SF-0.5-MD, FSN 6115-
ments supported.
935-8694.
(3) To determine allowances when support-
b. E x p l a n a t i o n
of
Military
Design
Generator
ing more than 100 of these equipments: First,
Set, serial numbers. Generator Set: The serial
divide the number of equipments supported by
n u m b e r of a Military Designed generator set (end
100 by moving the decimal two places left; second,
item) is comprised of four basic alpha-numeric
m u l t i p l y the result by the Quantity in the 51-100
c h a r a c t e r s to which is appended a numeric series
density column. Example, authorized allowance
corresponding in quantity to the number of set
for 51-100 equipments is 40; for 150 equipments
furnished.
m u l t i p l y 40 by 1.50 or 60 parts required.
c. F i r s t c h a r a c t e r ( a l p h a ) s p e c i f i e s t h e m a n u -
h. I-Year Allowance Per 100 Equipments/Con-
facturer. Definition as follows:
tingency Planning Purposes. Indicates
opposite
(1) J--Rett Electronics Inc
the fist appearance of each item the total quantity
(2) B--Bogue Electric Manufacturing Co
required
for
distribution
and
contingency
plan-
n i n g purposes. The range of items indicates total
d. S e c o n d
character
(alpha)
denotes
Hertz
or
q u a n t i t i e s of all authorized items required to pro-
vide for adequate support of 100 equipments for
(1)
A--60
Hertz
one year. Subsequent appearances of the same
(2)
B--400
Hertz
i t e m will have the letters "REF" in the allowance
(3) C--28 Volt DC
column.
e. T h i r d a n d f o u r t h c h a r a c t e r s ( n u m e r i c ) r e p -
i . Depot Maintenance Allowance Per 100 Equip-
r e s e n t the year of initial delivery.
ments. Indicates opposite the first appearance of
e a c h item the total quantity authorized for depot
f. F i f t h ,
sixth,
seventh
and
eighth
characters
maintenance of 100 equipments. Subsequent ap-
r e p r e s e n t the unit number sequence of sets manu-
p e a r a n c e s of the same item will have the letters
factured.
" R E F " in the allowance column, Items authorized
g.
Example:
JB66-0001
or
JB66-4000
(Rett
for use as required but not for initial stockage
E l e c t r o n i c s Inc., 400 Hertz, year of initial delivery
are identified with an asterisk in the allowance
1966, first and fourth thousandth set manufac-
column.
tured).
j. Illustration. This column is divided as fol-
h. E x p l a n a t i o n
of
Department
of
Defense
lows :
( D O D ) Model designations. DOD family of Mobile
(1) F i g u r e n u m b e r . I n d i c a t e s t h e f i g u r e
Electric
Power
sources
MEP
Model
Number
as-
number of the illustration in which the item is
signment.
shown.
(2) I t e m n u m b e r . I n d i c a t e s t h e c a l l o u t n u m -
Tactical
b e r used to reference the item in the illustration.
Utility
Rating KW Spark Ignition Engine Driven (SIED)
4.
Special
Information
DC
400 Hz
60 HZ
0.5
a. Identification of the usable on codes included
024A
019A
014A
i n the description column of this publication are:
Used on
Code
i. W h e n
requisitioning
X2
parts,
complete
Applies to all models.
Uncoded
s e r i a l numbers of end items must be given along
0.5 KW, Military Design 28 Volt DC, DOD
A
with end item FSN.
Model MEP-024A, serial number range
JC66-001 through JC66-0600, formerly
j. Repair parts mortality has been based on
Military
Model
DC-1.5-MD/28,
FSN
2000 hours operation per year.
6115-917-7355.
v