LUBRICATION
L05-6115-440-12
ORDER
1 JULY 1968
GENERATOR SET, GASOLINE ENGINE 7.5 KW, DC, 28 V; TWO-WIRE;
AIR COOLED; WHEEL MOUNTED,(JOHN R HOLLINGSWORTH CO.
MODEL JHGV7.5A) W/ WISCONSIN ENGINE MODEL MVH4D
Reference: C9100-lL
IntervaIs are based on normal hours of operations. Adjust
Clean parts with SOLVENT, dry-cleaning, or with OIL, fuel,
to compensate for abnormal operations and severe condi-
DieseI. Dry before Iubricating.
tions. During inactive periods, sufficient Iubrication must
be performed for adequate preservation.
Lubricate points indicated by dotted arrow shafts on both
Clean fittings before lubricating.
sides of equipment.
Relubricate after washing.
Drain crankcase when hot. FIII and check level.
FOLD
.
--
LUBRICANT q INTERVAL
INTERVAL q L U B R I C A N T
OE Crankcase FiII Cap
Air
Cleaner
OE
10
(See key)
(See key.) (Refill
CAUTION: When OES
oil reservoir to level
0il iS used the level
mark. Every 100 hours,
will be checked more
dissassemble entire
often.
unit, clean, reoil,
and reassemble.)
10
(Check
level.)
(Sealed Bearings;
No Lubrication Re-
quired)
100
0il Filter
(see note 3)
(Remove wheel, clean,
Crankcase Drain Plug
50
Inspect and lubricate
(Drain md refill.)
ble)
(See note 4)